Designed to Fit AnywhereThe ASCO SerieS 300 product line represents the most compact design of automatic power transfer switches in the industry. With space in electrical closets being at a premium, the use of wall or floor-mounted ASCO Power Transfer Switches assures designers optimum utilization of space.All transfer switches through 2000 amps are designed to be completely front accessible. This permits the enclosures to be installed flush to the wall and still allows installation of all power cabling and connections from the front of the switch. Cable entrance plates are also standard on the 1600 and 2000 amp units to install optional side-mounted pull boxes for additional cable bending space. |
![]() |
![]()
***Click on any transfer switch to add it to cart.
| Amps | Open Style Enclosure | Type 1 Enclosure | ||||
| 2 Pole | 3 Pole | 4 Pole | 2 Pole | 3 Pole | 4 Pole | |
30 |
||||||
70 |
||||||
104 |
||||||
150 |
||||||
200 |
||||||
230 |
||||||
260 |
||||||
400 |
||||||
600 |
||||||
800 |
||||||
1000 |
||||||
1200 |
||||||
1600 |
||||||
2000 |
||||||
2600 |
||||||
3000 |
||||||
*We can add Secure/Non-Secure Enclosure Options (UL Type 3R, UL Type 4, UL Type 12, UL Type 4X (304 Grade)) Please call 800-341-7027 for pricing or further discounts.
![]()
| Acc. # | Description | Price |
5 |
Test Switch |
STD |
6B |
Manual bypass of transfer to normal TD |
STD |
9A/9B |
ATS switch position indicating lights |
STD |
| 9C/9D | Source available lights | STD |
| 11C | Auto. engine exerciser with load/ no load switch | STD |
| 11BG | Programmable engine exerciser with normal and emergency available output contacts | |
| 14A/14B | ATS position indicating contacts, (1) for normal, (1) emergency | STD |
| 14AA/14BA | ATS position indicating contacts, (1) for normal, (1) emergency | |
| 17 | Provisions for remote transfer contact, witch automatic bypass if emergency fails, and normal is acceptable. | STD |
| 27 | Inphase monitor for motor load transfer | STD |
| 31F/M | Load disconnect contacts, with TD which operate before/after transfer | STD |
| 33 | Ground Lug | |
| 37B | 6' extension harness | |
| 37C | 9' extension harness | |
| 44A | Strip heater w/ thermostat, external 120V power source required | |
| 44G | Strip heaterw/ thermostat, wired to terminals: 208-600V | |
| 62W | Transfer to emergency alarm horn & silence switch | |
| 73 | Series 450 Surge Suppressor rated 65kA | |
| 72A | Series module (5110) | |
| 72E | Connectivity Module | |
| 123 | Hinged lockable polycarbonate window frame and weather gasket |
![]()
| Catalog # | Description | Price |
601815 |
Local Site Converter (RS232 to RS485) |
|
Vpi 32.15E |
PowerQuest Software |
|
5220T |
5220T Power Manager Xp. Transducer only no display included. Used for interface w/ ASCO monitoring equipment. 24VDC power required. |
|
| 732862-001 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 732862-002 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 5310 | Single channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. | |
| 5350 | Eight channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. |
![]()
| Kit # | Description | Price |
| K629830 | Programmable Engine Exerciser (Acc 11BG) | |
| K613127-001 | Strip Heater Kit, (100Watt) 120V (Acc.44A) | |
K613127-002 |
Strip Heater Kit, (100Watt) 208-600V (Acc.44G) |
|
K755257 |
Serial Module (Acc. 72A) |
|
K754603 |
Connectivity Module (Acc. 72E) |
|
| K609027 | Cable Pull Box (1600-2000 amp standard front connected switches) | |
K778330-001 |
Window Kit (Acc. 123) |
![]()
| Amps | Type 1 Enclosure | ||
| 2 Pole | 3 Pole | 4 Pole | |
70 |
|||
100 |
|||
150 |
|||
200 |
|||
225 |
|||
250 |
|||
400 |
|||
600 |
|||
800 |
|||
1000 |
|||
1200 |
|||
1600 |
N/A |
||
2000 |
|||
2500 |
|||
3000 |
|||
![]()
| Acc. # | Description | Price |
5 |
Test Switch |
STD |
6B |
Manual bypass of transfer to normal TD |
STD |
9A/9B |
ATS switch position indicating lights |
STD |
| 9C/9D | Source available lights | STD |
| 11C | Auto. engine exerciser with load/ no load switch | STD |
| 11BG | Programmable engine exerciser with normal and emergency available output contacts | |
| 14A/14B | ATS position indicating contacts, (1) for normal, (1) emergency | STD |
| 14AA/14BA | ATS position indicating contacts, (1) for normal, (1) emergency | |
| 17 | Provisions for remote transfer contact, witch automatic bypass if emergency fails, and normal is acceptable. | STD |
| 27 | Inphase monitor for motor load transfer | STD |
| 31F/M | Load disconnect contacts, with TD which operate before/after transfer | STD |
| 42TH3 | Reduced type 3R secure enclosure for 70-225A frame size only | |
| 44G | Strip heaterw/ thermostat, wired to terminals: 208-600V | |
| 62W | Transfer to emergency alarm horn & silence switch | |
| 72A | Series module (5110) | |
| 72E | Connectivity Module | |
| 73 | Surge Suppression |
| Accessory 134 100% SE Rated Breaker 300/386 | ||
Amp Size |
2 Pole List Price Adder |
3 Pole List Price Adder |
70 - 150 |
||
200 - 225 |
||
250 |
||
400 |
||
600 - 800 |
Contact Application Eng |
|
1000 - 2000 |
||
![]()
| Catalog # | Description | Price |
601815 |
Local Site Converter (RS232 to RS485) |
|
Vpi 32.15E |
PowerQuest Software |
|
5220T |
5220T Power Manager Xp. Transducer only no display included. Used for interface w/ ASCO monitoring equipment. 24VDC power required. |
|
| 732862-001 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 732862-002 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 5310 | Single channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. | |
| 5350 | Eight channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. |
![]()
| Kit # | Description | Price |
| K629830 | Programmable Engine Exerciser (Acc 11BG) | |
K613127-002 |
Strip Heater Kit, (100Watt) 208-600V (Acc.44G) |
|
K755257 |
Serial Module (Acc. 72A) |
|
K754603 |
Connectivity Module (Acc. 72E) |
![]()
| Series 300L | Type 1 Enclosure | Type 3R Secure Enclosure | ||||
| Amp | 2 Pole | 3 Pole | 2 Pole | 3 Pole | ||
200 |
||||||
400 |
||||||
![]()
| Acc. # | Description | Price |
5 |
Test Switch |
STD |
6B |
Manual bypass of transfer to normal TD |
STD |
9A/9B |
ATS switch position indicating lights |
STD |
| 9C/9D | Source available lights | STD |
| 11C | Auto. engine exerciser with load/ no load switch | STD |
| 11BG | Programmable engine exerciser with normal and emergency available output contacts | |
| 14A/14B | ATS position indicating contacts, (1) for normal, (1) emergency | STD |
| 14AA/14BA | ATS position indicating contacts, (1) for normal, (1) emergency | |
| 17 | Provisions for remote transfer contact, witch automatic bypass if emergency fails, and normal is acceptable. | STD |
| 27 | Inphase monitor for motor load transfer | STD |
| 31F/M | Load disconnect contacts, with TD which operate before/after transfer | STD |
| 44G | Strip heaterw/ thermostat, wired to terminals: 208-600V | |
| 62W | Transfer to emergency alarm horn & silence switch | |
| 72E | Connectivity Module | |
| 73V*1 | Single Phase Surge Suppression 240/120V | |
| 73V*3 | Three Phase Surge Suppression 208Y-120V | |
| SQ - D Normal & Emergency source breakers | STD | |
| SQ - D 42 circuit panelboard (does not include branch breakers) | STD |
![]()
| Catalog # | Description | Price |
601815 |
Local Site Converter (RS232 to RS485) |
|
Vpi 32.15E |
PowerQuest Software |
|
5220T |
5220T Power Manager Xp. Transducer only no display included. Used for interface w/ ASCO monitoring equipment. 24VDC power required. |
|
| 732862-001 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 732862-002 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 5310 | Single channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. | |
| 5350 | Eight channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. |
![]()
| Kit # | Description | Price |
| K629830 | Programmable Engine Exerciser (Acc 11BG) | |
K613127-002 |
Strip Heater Kit, (125Watt) 208-600V (Acc.44G) |
|
K754603 |
Connectivity Module (Acc. 72E) |
|
| K733433-001 | Single Phase Surge Suppression 240-120V | |
K733433-003 |
Three Phase Surge Suppression 208Y-120V |
![]()
| Series 300L | Type 4 Secure Enclosure |
Amp |
2 Pole |
50 |
|
100 |
![]()
| Acc. # | Description | Price |
5 |
Test Switch |
STD |
6B |
Manual bypass of transfer to normal TD |
STD |
9A/9B |
ATS switch position indicating lights |
STD |
| 9C/9D | Source available lights | STD |
| 11C | Auto. engine exerciser with load/ no load switch | STD |
| 11BG | Programmable engine exerciser with normal and emergency available output contacts | |
| 14A/14B | ATS position indicating contacts, (1) for normal, (1) emergency | STD |
| 14AA/14BA | ATS position indicating contacts, (1) for normal, (1) emergency | |
| 17 | Provisions for remote transfer contact, witch automatic bypass if emergency fails, and normal is acceptable. | STD |
| 27 | Inphase monitor for motor load transfer | STD |
| 31F/M | Load disconnect contacts, with TD which operate before/after transfer | STD |
| 37P1 | Appleton generator power input receptacle for 60Amp PTLC (Single Phase) | |
| 37P2 | Appleton generator power input receptacle for 100Amp PTLC (Single Phase) | |
| 37GF | 15A, 120V Duplex Outlet from GFCI in Load Center | |
| 44A | Strip heaterw/ thermostat, external 120V source required | |
| 72E | Connectivity Module | |
| 73VL1 | Series 458 Single Phase Load Side Surge Suppression 240-120V | |
| 73TL1 | Series 510 Single Phase Load Side Surge Suppression Line - Neutral Protection (includes 2 TVSS's) | |
| SQ - D Normal & Emergency source breakers | STD | |
| SQ - D 24 Circuit load center | STD | |
| 128FS | Optional Enclosure Stand for Floor Mounting |
![]()
| Catalog # | Description | Price |
601815 |
Local Site Converter (RS232 to RS485) |
|
Vpi 32.15E |
PowerQuest Software |
|
5220T |
5220T Power Manager Xp. Transducer only no display included. Used for interface w/ ASCO monitoring equipment. 24VDC power required. |
|
| 732862-001 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 732862-002 | 5220D Power Manager Xp. Transducer with display included. Mounted in 16Hx16Wx6.5D enclosure. Single Phase 120Vac power required. |
|
| 5310 | Single channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. | |
| 5350 | Eight channel annunciator directly connects Ethernet network. Supports 24VDC, 120VAC and 220VAC, requires 72E module. |
![]()
| Kit # | Description | Price |
| K629830 | Programmable Engine Exerciser (Acc 11BG) | |
K732212-003 |
Strip Heater w/ thermostat, externsl 120V source required |
|
K754603 |
Connectivity Module (Acc. 72E) |
|
| K733433-001 | Single Phase Surge Suppression 240-120V |
![]()

![]()

The ASCO Microprocessor Controller is used with all sizes of Power Transfer Switches. It represents the most reliable microprocessor controller in the industry and includes, as standard, all of the voltage, frequency, control, timing and connectivity functions required for most emergency and standby power applications.

Terminal provisions for connecting:


Performance Features
|
|
|
|
Series 300 ATS Optional AccessoriesAccessory 11BGA Programmable engine exerciser that provides for weekly or bi-weekly operation, includes one form C contact for source availability of normal and one contact for availability of emergency (contact rating 2 amps @ 30 Vdc, 0.5 amp @ 125 Vac resistive). The programmable engine exerciser incorporates a 7 day or 14 day time base with a digital readout display. Includes “with or without” load control selection for exerciser period. Accessory 14AA/14BAAuxiliary contacts to indicate position of main contacts. Two (2) for normal and two (2) for emergency position (one set is standard).Accessory 44AStrip Heater with thermostat for extremely cold areas to prevent condensation and freezing of this condensation. External 120 volt power source required. Accessory 44GStrip Heater with thermostat, wired to load terminals: 208-240, 360-380, 460-480, 550-600 volts. Contains wiring harnesses for all transfer switch sizes. Accessory 72A/72E*See “Connectivity Products”, Page 188 Accessory 123AProtective window that includes a poly-carbonate frame and weather gasket to provide secure access to the membrane interface for the type 1 enclosures. This lockable cover is an alternative to providing 3R secure enclosures. |
Window Kit(Accessory 123) |
The ASCO Service Entrance Power Transfer Switch combines automatic power switching with the necessary disconnecting, grounding, and bonding required for use as service entrance equipment. The power transfer switch meets all National Electrical Code requirements for service entrance use. Transfer switches generally are installed at facilities that have a single utility feed and a single emergency power source. ASCO SerieS 300SE products use two types of construction. Products 400 amperes or less, utilize a single enclosure including a service (utility source) disconnect circuit breaker, as well as the power transfer switch, grounding and bonding provisions. Products 600 amperes and above, utilize a multi-section switchboard construction including a service equipment section containing the service (utility source) disconnect circuit breaker, grounding, and bonding provisions. A second section contains the power transfer switch. Product Features:
|
|

ASCO 300L Automatic Power Transfer Load Center shown with optional quick connect Cam - Loc assembly and bottom Telco cabinet section (in type 3R secure aluminum enclosure)
ASCO POWERQUEST® communications products allow for the monitoring and control of power transfer switches in your Emergency or Standby Power Distribution System. Local and remote networks are supported with either single or multiple points of access and web-enabled communications allow access to your power system from anywhere around the wor


The 5500 Thin Web Server is a client-server application requiring no software to be installed on the client computer. When combined with ASCO Communication Interface Modules (5110, 5150), it provides the most comprehensive Intranet and Internet communication system for the monitoring and control of power transfer switches and engine generators located in your emergency or standby power distribution system.
The communication system allows multiple client access, from local or remote locations, and provides for the monitoring of up to 64 power transfer switches and eight (8) engine generators. In addition, automatic paging is provided for all alarm signals.
Digital PCS Platform |
|
| Asco Transfer Switch Comparison |
| Asco 300 Series Transfer switch spec brochure |